Brake - Configuration Tab

Caution
The parameters on this tab are set automati-
cally during brake calibration. Do not modify
these parameters unless advised to do so by
an MCE representative.
• Voltage: The voltage output to the brake coil
at various percentages of maximum voltage,
measured during calibration (see Caution
above).
• Output Timer: The amount of OFF time
during each cycle (delay before turning on
the brake output) required to output the
appropriate voltage to the brake coil at vari-
ous percentages of maximum voltage (see
Caution above).
• Current Reference: The voltage feedback
that represents the brake current at various
percentages of maximum voltage, measured
during calibration (see Caution above).
Table 9.4 Typical Configuration Values for 300V AC Brake Supply
Typical Values for a 300VAC Brake Supply
Percent of V max Voltage VDC
At 100%
At 90%
At 80%
At 70%
At 60%
At 50%
At 40%
At 30%
At 20%
At 10%
Output Timer Current Reference
249.639V
0.100ms
225.484V
2.084ms
200.253V
2.852ms
174.083V
3.492ms
149.155V
4.608ms
125.508V
4.580ms
99.164V
5.156ms
73.632V
5.735ms
49.092V
6.308ms
25.041V
7.012ms
Configuration - Brake Tab
0.243V
0.214V
0.194V
0.171V
0.149V
0.128V
0.105V
0.082V
0.069V
0.040V