Ice-Mor Multiple Output Relay Board Quick Reference; Output Connections - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

ICE-MOR Multiple Output Relay Board Quick Reference

The ICE-MOR board is a multi-purpose, relay-closure output board. ICE-MOR boards are used
in iControl elevator controllers and in iLink cartop enclosures.

Output Connections

Connect outputs as shown in your job prints. Outputs may be configured (in specific groups) to
provide either a path to ground or current to drive indicator lamps/LEDs.
Output State Selection
common. The common may be wired to provide a current source or a path to ground. The
groups are:
• Relays 1 — 4
• Relays 5 — 8
• Relays 9 — 16
• Relays 17 - 24
• Relays 25 - 32
The commons for the groups are determined by the connections made to board connector J5.
The appropriate connections are determined during the job survey. Each system is configured
before shipment. You need only connect outputs as shown on the job prints.
Table 6.20 ICE-MOR Board Connections
Connector
Output determined by Common
connection to board connector J5.
The outputs are divided into five groups. Each group shares a
Signal
iControl Circuit Board Quick References
Connector
1: Common
1: Common
AC2: MOR2, typical 18VAC
AC1: MOR1, typical 18VAC
Common 25 - 32
Common 9 - 16
Common 5 - 8
Common 17 - 24
Common 25 - 32
1: Common
Signal
6-107
6

Advertisement

Table of Contents