Fire Recall
Settings for fire recall.
• Fire recall door cycle time: Sets the door cycle time for the Fire Recall Door Cycle option.
When the car reaches the recall floor and doors are opened, the doors will then close after
the Fire Recall Door Cycle time expires (used for pressurised hoistway).

Fire Service - Fire Code

Displays the currently selected Fire Code and allows a different Fire Code to be selected.
• All parameters are in default state: Indicates that all of the fire service parameters
are set as specified by the selected code. If this is not the case,
has been
changed." is displayed.
• Name: Select the appropriate code from the drop down list.
• Year: Select the appropriate version (year) of the code.
• Default button: Sets the fire service parameters to the values specified by the selected
code, e.g. A17.1 - 2000.
• Latch the fire hat flashing: Flashing the fire hat is required by certain jurisdictions
whenever the hoistway or machine room smoke sensors are tripped. When these sensors
are reset, the fire hat continues to flash if this option is set. Otherwise the fire hat will
remain illuminated until fire service is deactivated.