Hall Call Eligibility

Use these controls to create up to eight different Hall Call Eligibility configurations. Each con-
figuration includes eligibility permissions/restrictions for the car. The active configuration can
be selected and run manually or by timer table.
The following controls are found on the Hall Call Eligibility tab.
• Select the Hall Call Eligibility configuration (1 - 8) you want to create or edit.
• Convert Front (Rear) Auxiliary Hall Call Riser to Front (Rear) Main Hall Call Riser: If,
when this configuration is active, you want one or both of the auxiliary hall risers to func-
tion as additional sets of main risers, enable the appropriate choice.
• Select car to configure: For a Simplex this will default to 1.
Eligibility Table
the remaining columns indicates that the associated hall call is eligible to be registered at that
floor. You can make a selection in a few different ways:
1. Click in individual cells to enable or disable, or
2. Click and drag in a column to select multiple floors, then click to Select allow calls or
Deselect to restrict calls, or
3. Click in the column head (i.e., Front Main Up) to highlight the entire column (all floors),
then use the Select or Deselect buttons.
4. When you are satisfied with your settings, click Send to send the data to the iBox.
5. Continue to create configurations (up to eight) as needed.
For each floor (listed in the left-most column), a check mark in any of