down hall call has been entered and the car has reached the floor from which that call
originated, or the doors are open and a car call is entered for a floor below. Timer
options are located on the Configuration > Car Operation > Devices tab.
• Front (Rear) Nudging Audible: This output is activated when door nudging has been
activated. Options located on Configuration > Car Operation > Passenger tab.
• Front (Rear) Door This Car Up: This output is active when the car is at the lobby floor
and has been selected as the next car to go in the UP direction.
• Front (Rear) Up Car Lantern: This output is activated (usually a single ding) to
announce the elevator's intention to go up after the doors start to open by operating
the front or rear in-car gong/lantern assembly. This will happen when an up hall call
has been entered and the car has reached the floor from which that call originated, or
the doors are open and a car call is entered for a floor above. Timer options are located
on the Configuration > Car Operation > Devices tab.
• Car Calls - Front COP 1
• Car Call - Front COP 1 light, Floor 1—150: Outputs to the front Car Operating Panel 1
lights.
• Car Calls - Rear COP 1
• Car Call - Rear COP 1 light, Floor 1—150: Outputs to the rear Car Operating Panel 1
lights.
• Car Calls - Front COP 2
• Car Call - Front COP 2 light, Floor 1—150: Outputs to the front Car Operating Panel 2
lights.
• Car Calls - Rear COP 2
• Car Call - Rear COP 2 light, Floor 1—150: Outputs to the rear Car Operating Panel 2
lights.
• Position indicators Binary Outputs I
• Binary Position Indicator I, Output 1— 8: Outputs 1 through 8 to Binary Position Indi-
cator I. Outputs I will stay active during Fire Service.
• Position indicators Binary Outputs II
• Binary Position Indicators II, Output 1—8: Outputs 1 through 8 to Binary Position
Indicator II. Outputs II will deactivate during Fire Service.
• Position indicators Single Outputs I
• Position Indicators Single I, Floor 1—64: Outputs to one line per floor position indica-
tors. Outputs I will stay active during Fire Service.
• Position indicators Single Outputs II
• Position Indicators Single II, Floor 1—64: Outputs to one line per floor position indica-
tors. Outputs II will deactivate during Fire Service.
• Position indicators Rotodial Outputs I
• Rotodial Position Indicators I, Output 1—3: Outputs created for the "Rotodial" brand
position indicators. These three outputs change in a specified pattern to cause the
rotodial device to rotate in the appropriate direction. Outputs I will stay active during
Fire Service.
• Position indicators Rotodial Outputs II