iView - Controller View
Fire Service Override
• Security does not override fire service: This is the default state.
• Override fire service/heat detectors when the following security configura-
tions are active: This option is intended only for an installation where security is of
prime importance and where fire service/heat detectors operation would compromise that
security. If this option is selected, fire service/heat detectors operation will not be allowed
if Master security is active and one of the checked Security Configurations is active (Sys-
tem > Configuration > Security > General > Status). The active Security Configuration
must have at least one floor secured or locked, regardless of the status of car call enable or
car call enable override inputs. If a fire sensor/heat sensor or switch is activated while
Master security is active, and then Master security is deactivated, fire service/heat detec-
tors operation will be allowed. However, if fire service/heat detectors operation is already
in progress and Master security is then activated, fire service/heat detectors operation will
continue.
• Security configuration 1 (through 8): Check the Security configuration(s) which,
when active, will override fire service as described above.
Caution
Changing Fire Code parameter settings may cause you to be out of compliance with the
selected code and may require a variance. Parameter settings that are in compliance with
the selected code are shown with an underline.
comply with the selected code, it will appear in
Firefighter's car
• No in-car firefighter's switch: Check if the car does not have an in-car firefighter's
switch (Required for British Fire Code EN 81-72).
• Designated firefighter's car: Check if the car does not have an in-car firefighter's
switch, but is a designated firefighter's car. Upon completion of Fire Phase I it will then
automatically go to Fire Phase II.
Fire Recall
• Fire recall door cycle time: Sets the door cycle time for the Fire Recall Door Cycle
option. When the car reaches the recall floor and doors are opened, the doors will then
close after the Fire Recall Door Cycle time expires (used for pressurised hoistway).
9-46 Manual # 42-02-2222
If a setting is changed to one that does not
RED.