MCi iControl User Manual page 122

For ac elevators
Table of Contents

Advertisement

Inspection Mode
4. Place a magnet on the rail as shown in Figures 4 and 5. below. iLand Compact must be
adjusted so that the Leveling Sensors are centered on the magnet with the face of the
sensors 1/8" from the surface of the magnet.
Figure 4. Magnet position on the rail (side view)
The front floor leveling magnet and
leveling sensors are shown in this
picture. The rear floor
leveling magnet and sensors, if
applicable, is mounted on the oppo-
site side of the rail.
Floor Leveling Magnet
Leveling Sensor Bracket
Leveling Sensor Bracket
adjustment screws
Figure 5. Magnet position on the rail (top view)
The magnet should be
on an angle of approx-
imately 12 degrees
with respect to the
back surface of the
rail.
The Leveling Sensors
should line up with the
center of the magnet
and be positioned 1/8"
from the magnet
surface.
3-6 Manual # 42-02-2222
Leveling Sensors
12 degrees