Table 8.3 Controller - Configuration Tabs
Tab
Sub-Tab
Pattern
Common
Modes
Terminal
Switches
Timer Tables
Table 8.4 Controller - Diagnostics Tabs
Tab
Sub-Tab
Operational
Status
Data Trap
Diagnostic
Car Operation Displays status of car operation input and output flags, including front and
Flags
Motion
Drive
Safety
Diagnostic
Outputs
Event Log
Fault Bypass
Terminal
Switches Status
Virtual
Oscilloscope
8-28 Manual # 42-02-2222
Display and edit parameters common to all pattern profiles. Position
encoder resolution, leveling and releveling speeds, pattern scaling, dead
zone distance, door pre-opening distance, and position synchronization by
floor or terminal switches
Parameter settings for Standard, Earthquake, Emergency power, Emer-
gency slowdown, Correction, Inspection, and Alternate 1-2 profiles.
Position margin settings for up and down normal terminal and emergency
terminal switches, and Overspeed 1 margin setting
Programming of timed operations (Sabbath, Swing and Auto stop opera-
tion).(see page
9-135).
Displays the car status including: motion, speed, position, pattern, motor
and brake, processor, in-service, leveling, door locks, faults and car status
(see page
9-8).
Use this tool to record and analyze controller data including input and
output states, internal flags and parameter values
rear doors, e.g. car call above, car call below. Click arrow buttons to dis-
play dependent outputs
Displays the status of Passenger (automatic) and Inspection mode motion
related inputs and outputs, e.g. Ready, Synchronization and Qualifier sta-
tus.
Displays the status of Drive related inputs and outputs, e.g. Up direction
request, Pattern enable, and Motor run mode.
Displays the status of Safety related inputs and outputs, e.g. Car top exit
open, Governor open, and Safety (Car) open.
Selection and display of up to sixteen system outputs for monitoring or
diagnosis. Hundreds of outputs are available
Display of recorded controller events
Enable/disable selected system faults to facilitate adjustment and testing.
Display of faults currently bypassed
Displays the learned terminal switch speeds and positions, overspeed and
position fault thresholds and last pass positions and speeds
(see page
9-19).
An on-board oscilloscope with software selection of test point signals to
be monitored and customizable display
Content
(see page
9-128).
Content
(see page
9-12).
(see page
(see page
(see page
9-17).
(see page
(see page
9-134).
(see page
9-11).
9-13).
9-14).
9-21).