iView - Controller View
System status
• Inspection - lights when the iBox INSPECTION switch is in the INSP position.
• Test - lights when the iBox TEST switch is ON.
• Fault bypass - lights when the iBox FAULT/FUNCTION BYPASS switch is ON.
• Bypass active - lights when any fault bypass is active.
Bypass status
• Active bypasses - indicates the number of active bypasses.
• Time remaining - the bypass remains active for fifteen minutes from the time the iBox
Fault/ Function Bypass switch is turned ON. This display indicates the remaining time.
When the time elapses, the message window indicates "FAULT BYPASS SWITCH TIMED
OUT". If you need additional time, turning the Fault/Function Bypass switch to OFF and
then back to ON within one second will reset the selected bypasses.
• Message window - shows instructional information.
Fault Bypasses
ignored and the system will not respond to the fault as programmed.
Table 9.3 Fault Bypasses
Drive inspection overspeed
Drive enable feedback
Brake switch
Position quadrature
Quadrature speed deviation
Buffer test
Limit switch checksum
UNT1 through 5 Level 1 Overspeed
UNT1 through 5 Level 2 Overspeed
UETS Level 2 Overspeed
UNT1 through UNT5 Position
UETS Position
Safety Contract Overspeed
Safety Leveling Overspeed
9-18 Manual # 42-02-2222
The following bypasses are provided. When enabled, the fault will be
Tech error
Brake voltage not on
Position reversed
Quadrature speed threshold
Motion start
Direction limit
Outer level Correction
DNT1 through 5 Level 1 Overspeed
DNT1 through 5 Level 2 Overspeed
DETS Level 2 Overspeed
DNT1 through DNT5 Position
DETS Position
Safety Inspection Overspeed
Tach Failure