System Options
If the distance between where the target bracket attaches to the floor and the center of the floor
is greater than 20% of distance "A" (see Figure 8.2), an alternate mounting method may pro-
duce better results.
• Example: If distance "A" is 10'
Then 20% of 10' is 2'
Therefore, if the target bracket attaches to floor more than 2' from the center of the chan-
nel, an alternate method of mounting is suggested (see Figure 8.5).
Figure 5.5 Alternate Mounting Location for Sensor and Target
When mounting inside the channel is too great a percentage (+20%) of Distance 'A'
try mounting sensor outside the channel.
Alternate location for
sensor and target on
outside of channel
Figure 5.6 Typical Support Assembly for Target Bracket
5-66 Manual # 42-02-2222
Center of Floor
The dimension shown must be a
minimum of 3/8" to provide clear-
ance for floor to sag
3/8"
Center of Gravity
Front of Car