MCi iControl User Manual page 564

For ac elevators
Table of Contents

Advertisement

iView - Controller View
• .Car Call Enable 1 - Front
• Car Call Enable 1 - Front, Floor 1 —150: Per floor, non-serial inputs from car call
enable 1 - front door device (card reader or keypad, etc.).
• Car Call Enable 1 - Rear
• Car Call Enable 1 - Rear, Floor 1 —150: Per floor, non-serial inputs from car call enable
1 - rear door device (card reader or keypad, etc.).
• Car Call Enable 2 - Front
• Car Call Enable 2 - Front, Floor 1 —150: Per floor, non-serial inputs from car call
enable 2 - front door device (card reader or keypad, etc.).
• Car Call Enable 2 - Rear
• Car Call Enable 2 - Rear, Floor 1 —150: Per floor, non-serial inputs from car call enable
2 - rear door device (card reader or keypad, etc.).
• Motor and Drive
• Governor Speed Reduction Switch: Input from Governor Speed Reduction Switch.
• Sheave Brake Monitor: Input from the sheave brake monitor.
• Brake Switch: This input can be used in place of input SP2D. The "Switch" parameters
on the Controller > Configuration > Brake > Control tab determine the state of the
input (high or low) that indicates the brake is picked.
• System Configurations (Simplex)
• Hall Call Eligibility Config (1 - 8): Activation of a Hall Call Eligibility Configuration (1 -
8) input causes the respective configuration to be the active configuration.
• Parking Config (1 - 8): Activation of a Parking Configuration (1 - 8) input causes the
respective configuration to be the active configuration.
• Parking Eligibility Config (1 - 8): Activation of a Parking Eligibility Configuration (1 -
8) input causes the respective configuration to be the active configuration.
• Mode of Operation Config (1 - 8): Activation of a Mode of Operation Configuration (1 -
8) input causes the respective configuration to be the active configuration.
• Security Config (1 - 8): Activation of a Security Configuration (1 - 8) input causes the
respective configuration to be the active configuration.
• Master Security Override input: Activation of this input overrides all elevator security.
• Hall Call Security 1 Override input: Activation of this input overrides Hall Call Security
1 security.
• Hall Call Security 2 Override input: Activation of this input overrides Hall Call Security
2 security.
• Hall Calls - Aux Front Down
• Hall Call - Aux Front Down Button (1 - 150): Non-serial inputs from front aux down
hall call buttons.
• Hall Calls - Aux Rear Down
• Hall Calls - Aux Rear Down Button (1 - 150): Non-serial inputs from rear aux down hall
call buttons.
9-112 Manual # 42-02-2222