MCi iControl User Manual page 506

For ac elevators
Table of Contents

Advertisement

iView - Controller View
• During Fire Phase II Hold:
• Keep doors open and disable door close button): Hold the car doors open during Fire
Phase II Hold, bypassing the Door Close Button.
• Cancel car calls: During Fire Phase II Hold, cancel all car calls and prevent registration
of new car calls.
• Conditions for stopping / disabling doors:
• Emergency stop switch stops doors.
• Emergency stop switch disables door opening.
• Emergency stop switch disables door closing.
• Door stop button stops doors.
• Door stop button disables door opening.
• Door stop button disables door closing.
• Miscellaneous:
• Auto close doors if car away from recall floor: Unless the Door Open Button is pressed,
always keep the doors closed when away from the recall floor.
• Nudge doors: Close doors at nudging speed during in-car firefighter operation.
• Cancel Fire Phase II car calls if car is at recall floor and DOB is pressed: Cancel car calls
during in-car firefighter operation if the car is at the recall floor and the Door Open
Button is pressed.
• Fire Phase II bypasses stop switch: Bypass the Stop switch during in-car firefighter
operation.
• Enable safe edge during firefighter service: Enable the door safety edge during in-car
firefighter operation.
• Fire Phase II cancel car call upon door reopen: During in-car firefighter operation,
cancel car calls if a door reopens.
• Keep doors open during Fire Phase II: Enabling this option will cause the doors to
reopen as soon as the Door Close button is deactivated, even if the doors have fully
closed (as long as the car is not moving).
• Car emergency stop switch cancels car calls: Cancel car calls when the car emergency
stop switch is activated while on in-car firefighter operation.
• Do not move car to next floor after an emergency stop: During in-car firefighter opera-
tion, the car shall not be moved to the next floor after an emergency stop.
• Enable the in-car fire switch upon power up: In order to comply with ASME A17.1-
2000 code, when this parameter is checked, after power up, changes to the In-car Fire
Switch are recognized regardless of the position of the doors, until the doors have fully
opened once.
• Sync towards the fire recall floor: The car shall move towards the fire recall floor when
performing a floor sync operation.
• Enable in-car fire switch if doors have opened once: The In-car Fire Switch shall be
recognized regardless of the position of the doors, if the doors have been fully opened
once at the fire recall level. Note - This option must be checked for elevators with
manual doors that must comply with the ASME A17.1-2000 or later code.
• Disable door contact monitoring during fire phase II: Specifies that door contact mon-
itoring shall be disabled during fire phase II (required for New York 2000 fire code).
• New car call registration cancels previous car call: Specifies that registration of a new
car call shall cancel the previous call (required for British Fire Code EN 81-72).
9-54 Manual # 42-02-2222