MCi iControl User Manual page 668

For ac elevators
Table of Contents

Advertisement

iView - System View
• CFSS call enable 1 (2) - CFSS mode 1 front input: When active, a valid CFSS mode 1 call
at the associated secured floor, front opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
• CFSS call enable 1 (2) - CFSS mode 1 rear input: When active, a valid CFSS mode 1 call
at the associated secured floor, rear opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
• CFSS call enable 1 (2) - CFSS mode 2 input: When active, a valid CFSS mode 2 call at
the associated secured floor, can be registered. Select the floor number in the Associa-
tion column. (CFSS mode 1 and 2 are user-assignable operating modes typically used
for medical emergency calls, attendant calls, etc.)
• CFSS call enable 1 (2) - CFSS mode 2 front input: When active, a valid CFSS mode 2
call at the associated secured floor, front opening only, can be registered. Select the
floor number in the Association column. (CFSS mode 1 and 2 are user-assignable oper-
ating modes typically used for medical emergency calls, attendant calls, etc.)
• CFSS call enable 1 (2) - CFSS mode 2 rear input: When active, a valid CFSS mode 2 call
at the associated secured floor, rear opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
• Security Override
• Security override - Master security override input: When active, all secured calls are
enabled. All secured car and hall calls will behave as though unsecured. Locked calls
will remain locked.
• Security override - Hall call enable 1 override input: When active, all Enable 1 secured
hall calls are unsecured. Locked calls will remain locked.
• Security override - Hall call enable 2 override input: When active, all Enable 2 secured
hall calls are unsecured. Locked calls will remain locked.
• Split bank hall calls: When enabled and active, split bank operation allows a single control
group of cars to be controlled as though it were two separate groups. These inputs provide
connection points for the auxiliary and main riser hall call buttons for the cars split from
the group (Bank B).
• Bank B hall call - Down aux front
• Bank B hall call - Down aux rear
• Bank B hall call - Up aux front
• Bank B hall call - Up aux rear
• Bank B hall call - Down main front
• Bank B hall call - Down main rear
• Bank B hall call - Up main front
• Bank B hall call - Up main rear
10-58 Manual # 42-02-2222