iView - System View
System I/O - Bus Tab
The Bus tab allows you to see the status of the system busses (1 - 4), create an inventory of
devices on the busses and to test device functionality in comparison to the inventory.
Bus Status
• Connected: Lights green when the selected bus is properly connected.
• Bus Voltage: Lights green when serial bus voltage is within normal limits.
• Driver VDC: Lights green when Serial Hall Call Driver (J2) voltage is within normal limits.
• Node Control: Lights green when nodes respond correctly.
• Bus Enabled: Lights green when the selected bus is enabled.
• High Current: Lights red when bus current demand is excessive.
Wrapback Option
associated hall call button is pressed (rather than waiting for a response from the group control-
ler to light the lamp).
10-60 Manual # 42-02-2222
LEDs light to indicate the status of each bus.
When enabled, hall call lamps are lighted immediately when the