TORQMAX F5 Drive Parameters Quick Reference
This section includes quick reference information for the TORQMAX F5 drive parameters.
Please refer to the F5 drive manual provided with the iControl for a detailed explanation.
Caution
For Permanent magnet (PM Synchronous) motors, consult the following sections of the
TORQMAX F5 Drive manual before roping the machine, 5.5 PM Synchronous Motors, 5.8
Encoder Feedback and 5.11 Running the Motor.
Table 11.6 TORQMAX F5 Drive Parameters Quick Reference for iControl AC
WARNING: Do not change drive parameters while the elevator is running. Incorrect drive parame-
ters can cause erratic elevator operation. Parameters with an asterisk (*) must be set correctly
for your specific motor/machine. Refer to the drive adjustment manual for detailed information.
Digital
Operator
Parameter Description
Display
Signal operating mode:
AbSpd = Absolute Analog Speed
d SPd = Digital speed control
A tor= Analog torque control
LF.02
A Spd= Analog speed control
SErSP = Serial Com. Speed Control
bnSPd = Binary Speed Selection
S POS = Serial Position Feedback
LF.03
Drive configuration:
run = run mode
conF = Configuration (5 minute time limit)
Stop = Drive Stopped, Motor cannot run.
S Lrn = activate auto tune
I Lrn = Inertia Learn. Learns system inertia.
P Lrn = Pole Learn. PM motor pole positions.
SPI = Learns absolute encoder position for PM
motor without sheave movement. ****
OStST = Allows car to over speed for one run
without changing drive parameters
(see also LF.49).****
Motor selection: Displays mode selected using
LF.04
US.4 and US.10
LF.05
Drive fault auto reset
LF.08
Electronic motor overload protection
Electronic overload current:
LF.09
PM- Not visible, auto set same as LF.12.
Rated motor power
LF.10
PM- Read only, auto calc.
LF.11
Rated motor speed
LF.12
Rated motor current
LF.13
Rated motor frequency
Rated motor voltage
IM - Name plate rated voltage (120 - 500V)
LF.14
PM - No-load, phase-to-phase back EMF rms
voltage LF.11 (1 - 32000V/krpm)
TORQMAX F5 Drive Parameters Quick Reference
Unit
-
-
-
1
-
A
HP
rpm
A
Hz
V
Setting
Default
Range
Setting
AbSpd
d SPd
A tor
bnSPd
A Spd
SErSP
bnSPd
run
conF
Stop
S Lrn
conF
I Lrn
P Lrn
SPI
OStST
Read only.
-
See US.10
0-10
5
on/off
off
1.0 - 110%
8.0
Rtd
0.00 -
5.0
125.00
10.0-6000 1165 or 150 *________
1.0 - 110%
8.0
Drive rated
4.0 - 100.0
60.0
-
230/460
Factory
Setting
*________
run
***
5
on
*________
IM*______
*________
*________
11
*________
11-27