Inspection Mode

iLand Status LEDs

The iLand signal board enclosure reveals status LED sets for the front and rear floor leveling
sensors and the position encoder sensor. Refer to the illustration below.
Figure 9. iLand Status LEDs
Front floor leveling sensors:
- Up Leveling Up Marker (ULM)
- Door Zone (DZ)
- Down Leveling Marker (DLM)
Position Encoder Index
- LED turns on once per
wheel revolution, at the
zero index point.

iView Parameter Setting

The Position Encoder resolution parameter on the iView Controller > View > Configuration >
Pattern > Common tab must be set to 348 pulses per foot for the iLand Compact landing sys-
tem.
3-12 Manual # 42-02-2222
Position Encoder quadrature
pulse indicators. When the
elevator is in motion, these
LEDs light alternately,
90 degrees out of phase:
- DP2, DP2
Position Encoder Magnet
- when the adjustment is
correct both MAGIN and
MAGDE are off.
Rear floor leveling sensors:
- Up Leveling Marker (ULM-R)
- Door Zone (DZ-R)
- Down Leveling Marker (DLM-R)
Set to 348 pulses/ft.