Load Weigher Learn Procedure - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Final Adjustment

Load Weigher Learn Procedure

1. Display the Load Weigher layout (View > Layouts > Load Weigher).
2. Enter the Start floor (floor at which the test weights are located) on the Setup > Load
weigher tab.
3. Acquire "Write privilege" (Write privilege > Acquire) and place the iBox Learn switch in
the ON position.
4. With the car operating in normal Passenger operation, follow the step-by-step instruc-
tions that appear on the Setup > Load weigher tab.
Abort Calibration
stop the learning process. (For example, you started a Full Load learn and realized the test
weights were not in the elevator.) The car will return to the start floor where you may restart the
learn procedure.
Clear Learned Values
cesses have been successfully run and values stored. Clicking on the Clear button will immedi-
ately erase the stored values. You must then repeat the learning process to learn and store new
values.
4-34 Manual # 42-02-2222
If necessary during a learning process, click on Abort to immediately
Lighted Empty and Full Learn indicators mean that the pro-

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents