• Sabbath trip interval timer: Specifies the interval between Sabbath operation trips. During
the time between trips, the car operates in Passenger mode. A value of Non-stop = contin-
uous Sabbath operation.
• Sabbath door open timer: Specifies the amount of time the doors shall remain open at
each floor during Sabbath operation.
• Sabbath operation status LED: LED lights green when Sabbath operation is activated.
• Activate/Deactivate button: Sabbath operation can be activated/deactivated using this
button. When Sabbath operation has been activated, the button caption changes to "Deac-
tivate". Sabbath operation can also be activated/deactivated via a key switch-input, iMoni-
tor command or a timer.
• Sabbath Operation Floors: Specifies the floors (front, rear or both openings) that are to be
serviced during Sabbath operation.
• To add or remove the check mark in an individual cell, click the cell.
• To add or remove check marks from a group of cells, click and drag to select the cells,
then click Select or Deselect.
• To add or remove check marks from a whole column, click the column label, then click
Select or Deselect.
Configuration - Car Operation