Troubleshooting
Figure 6.12 Simplified Rope Gripper Operation
RG1
RG2
RG5
RG7
Manual switch:
Open = manual operation, rope gripper disabled
Closed = normal operation, rope gripper enabled
6-110 Manual # 42-02-2222
Rope Gripper
120VAC
Rope Gripper Power Supply
120VAC
RG OK Safety A
RG OK Safety B
Closed = Rope Gripper Retracted
Open = Rope Gripper Actuated