• Remote User Outputs: Up to 32 outputs may be defined by the user on the Remote Out-
puts tab. The first four of these outputs may be included in timer tables and triggered by
the timer. Outputs may also be manually triggered from the Remote Outputs > Trigger
tab. Once defined, the outputs are associated with a physical output address using the Sys-
tem I/O or I/O Boards tab. Outputs may be latching or toggle, active high or low, and are
intended to be used to drive system inputs as required by individual sites.
• Remote (01 - 32)
• User Defined Events: Up to 10 inputs may be used to trigger a specific event message to be
posted to the system event log. The user defines the text of the event on the User Events
tab, then assigns a physical address (location) to the input using the System I/O tab.
• User Event 1 (- 10)
• Active Mode of Operation Outputs:
• Balanced: Active when the system is operating in balanced mode, typically to drive a
visual indicator.
• Lobby Peak: Active when the system is operating in lobby peak mode, typically to drive
a visual indicator.
• Demand Up Peak: Active when the system is operating in demand up peak mode, typi-
cally to drive a visual indicator.
• Demand Down Peak: Active when the system is operating in demand down peak
mode, typically to drive a visual indicator.
• Association Column:
Choices selectable in this column are dependent on the adjoining Input/Output selection
as follows:
• For hall calls, the floor Association selection is presented.
• For emergency power related functions, generator assignment is presented (Gen1 or
Gen2).
• For recall/car related functions, the car Association selection is presented.
Note
Remember, the above settings are all pre-configured before the controller is shipped from MCE.
You should need only to connect inputs and outputs according to your job prints. These settings
should not be changed or edited unless hardware affecting these settings is being replaced. In
these instances, follow specific instructions provided by MCE.
Configuration Tabs - System I/O