Table 6.3 iControl Messages
Cartop Exit no Counterweight Configuration Error, CTEX NO CWI CFG ERROR
Description: Car Top Exit, on the Safety tab, has been checked but Counter weight displacement detection,
on the Car Operation - Earthquake tab, has not been checked. A car equipped with both Earthquake Opera-
tion and Cartop Exit must have a counterweight derailment device.
Car Reaction: The car is not allowed to run until the problem is corrected.
Troubleshooting:
1. Verify the status of the Car Top Exit parameter (Safety tab).
2. Verify the status of the Counter weight displacement detection parameter (Car Operation - Earthquake
tab).
Cartop Firmware Update Mode, CARTOP FW UPDATE MODE
Description: The cartop processor is not running the cartop application firmware but is instead either waiting
for or processing the firmware update (iView > File > Firmware update).
Car Reaction: The car is not allowed to run until the procedure is completed.
Cartop Inspection Disabled, CT INSP. DISABLED
Description: Cartop inspection operation has been disabled.
Car Reaction: The car cannot be run on cartop inspection operation.
Troubleshooting:
1. Check for any car status that might prevent cartop inspection operation, e.g. earthquake.
2. Check for the Stuck Inspection Input Fault.
3. Check all inspection buttons (Enable, Up, Down) and verify that none are stuck in the ON position.
Cartop Inspection Enabled
Description: Cartop inspection operation which was previously disabled is now enabled.
Cartop Inspection Inputs OK
Description: One or more previously stuck cartop inspection inputs (Enable, Up, Down) have been deacti-
vated (see Stuck Cartop Inspection Input message).
Cartop Inspection Operation, Cartop Inspection, Cartop Insp
Description: The car has been placed in Inspection mode using the cartop inspection switch.
Car Reaction: The car enters inspection mode and uses the Inspection pattern settings.
Cartop Inspection Unintended Motion Fault, CARTOP INSP UIM FLT
Description: An unintended motion fault was detected while the car was being operated on Cartop Inspection
Operation.
Car Reaction: Car motion stopped after 24 inches of travel. The safety circuit is opened.
Troubleshooting:
1. Check the iView Event Log for related events.
2. Troubleshoot and correct any initiating problems.
3. Press iBox Fault Reset.
4. Test.
Cartop Power Loss
Description: A loss of power was detected by the iLink processor.
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
1. Check 1, 2, and 3 bus terminal voltages from iControl, through traveler, to car terminal strip.
2. Refer to job print drawing CT, check strip to iLink connections.
3. Check iLink fuses F1 and FCT1.
CFSS Mode 1 at Floor Activated, CFSS 1 at Floor. See CFSS Mode 1 In-car Activated.