Before Release To Passenger Operation - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Before Release to Passenger Operation

Danger
Before the elevator can be turned over to normal passenger use, it is important that no
safety function or circuit remains bypassed. Items to check include, but are not limited to:
• All safety switches set to the OFF position
• No jumper between SB and 3 (iBox)
• No jumper between SAFH and 3 (iBox)
• Learn and Fault/Function switches set to OFF (iBox)
• TORQMAX Drive: Parameters LF.20 Contract Speed and LF.42 High Speed set to their
original values. Also, set LF.57 Speed Following Error = 1 (ON)
• No jumper between Gov and 3 (iBox)
• Pattern Scaling set to 100% (Pattern screen/Common tab)
Note
If this is a local car (part of a group), the "Car identifier" parameter, on the Configuration >
General > General tab, must be set so that the Group controller can identify the car to which it is
communicating,
defaulted to 1. The Car Identifier range is from 1 to 20. The Car identifier for each car in a Group
must be unique (no duplicates).
see "Configuration - General" on page 9-95
Before Release to Passenger Operation
Initially the Car identifier is
4
4-57

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents