Table 6.24 iBox Field Connections on ICE-SAF Board
Source
Connection
TX+
TX-
SHLD
RX+
RX-
SHLD
DZ
ULM
DLM
INCT
ICTU
ICTD
INCP
ICPU
ICPD
INA
ESC
DCL
DOL
DPM
iControl Circuit Board Quick References
iBox transmit, positive going serial communication stream from iBox to
iLink. Connects to iLink ICE-CTP Board terminal RX+. TX+ and TX-
comprise a differential communications pair.
iLink" on page
3-13.
iBox transmit, negative going serial communication stream from iBox to
iLink. Connects to iLink ICE-CTP Board terminal RX-.
Shield connection for twisted-pair TX+/TX-
iBox receive, positive going serial communication stream from iLink to
iBox. Connects to iLink ICE-CTP board terminal TX+. RX+ and RX-
comprise a differential communications pair.
iBox receive, negative going serial communication stream from iLink to
iBox. Connects to iLink ICE-CTP board terminal TX-.
Shield connection for twisted-pair RX+/RX-
Door Zone Sensor input. Activated = 110 VDC.
Up Leveling Marker Sensor input. Activated = 110 VDC.
Down Leveling Marker Sensor input. Activated = 110 VDC.
Cartop Inspection Station INSP/AUTO Switch input. Activated = 110
VDC.
Cartop Inspection Station UP Button input (includes SAF button). Acti-
vated = 110 VDC.
Cartop Inspection Station DN Button input (includes SAF button). Acti-
vated = 110 VDC.
COP Inspection Station INSP/AUTO Switch input. Activated = 110 VDC.
COP Inspection Station UP Button input. Activated = 110 VDC.
COP Inspection Station DN Button input. Activated = 110 VDC.
Car Panel (Hoistway) Access Enable switch input. 0 VDC active signal
level. Off = 110 VDC.
Car Panel Emergency Stop switch input. 0 VDC active signal level stops
car. Off = 110 VDC.
Door Close Limit input. Door fully closed, input inactive, 0 VAC. Door not
closed signal level, 120 VAC.
Door Open Limit input. Door fully open, input inactive, 0 VAC. Door not
open signal level, 120 VAC.
Door Position Monitor input. Door closed, input inactive, 120 VAC. Door
not closed, 0 VAC.
Signal Description
Please refer to "Installing