MCi iControl User Manual page 339

For ac elevators
Table of Contents

Advertisement

iControl Messages
Table 6.3 iControl Messages
iControl Messages
Retiring Cam Door Lock Fault Activated, Retiring Cam Door Lock Fault, RETIRING CAM DLK FLT
Description: The door locks have failed to make up within a pre-determined user-adjustable time after a user
adjustable number of attempts to lock the doors. This fault is detected on cars equipped with a retiring cam
door lock mechanism.
Car Reaction: Car is taken out of service and doors re-open fully. The doors can be closed with constant pres-
sure on the door close button.
Troubleshooting:
1. Check the door locks and the retiring cam circuitry.
2. Verify that the related user-defined parameters are correct.
3. This fault is cleared by any mode of operation change or if the doors are closed with constant pressure
on the door closed button.
Retiring Cam Door Lock Fault Deactivated. See Retiring Cam Door Lock Fault Activated
Retiring Cam Protection Fault Activated, Retiring Cam Protection Fault, RET CAM PROTECTIN FLT
Description: The retiring cam output has been activated for a pre-determined user-adjustable time after the
doors have successfully been locked. This fault is monitored in the event the car fails to reach its destination.
Car Reaction: Emergency stop if the car is traveling when the fault is detected. The car is taken out of ser-
vice. If the car is at a landing, the doors shall re-open fully.
Troubleshooting:
1. Check the door locks and the retiring cam circuitry.
2. Verify that the related parameters are correct.
3. This fault is cleared by any mode of operation change or by the iBox Fault Reset button.
Retiring Cam Protection Fault Deactivated. See Retiring Cam Protection Fault Activated
Sabbath Operation Activated, Sabbath Operation, SABBATH OPERATION. The elevator is operating in
Sabbath mode initiated by a software command, switched input or timer. Sabbath mode allows the elevator
to operate, serving the building without requiring buttons to be pressed for hall calls or car calls. Car behav-
ior is determined by parameters located on the Car Operation Configuration > Sabbath tab.
Sabbath Operation Deactivated. See Sabbath Operation Activated.
Safety A Contract Overspeed Fault, SPA COS FAULT
Description: The car has exceeded the Contract Overspeed setting (iView, Safety Configuration screen). This
fault may be bypassed on the Diagnostics > Fault Bypass tab.
Car Reaction: Emergency Stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
6
1. The fault will automatically clear 5 seconds after the car stops. The car is then allowed to run again.
2. Check the contract overspeed parameter for proper setting (iView/Safety Configuration/General).
Safety A DETS Level 2 Speed Fault, SPA DETS L2 SPEED FLT
Description: The car contacted the Down Emergency Terminal Switch while traveling at over 95% of contract
speed. This fault may be bypassed on the Diagnostics > Fault Bypass tab.
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
1. The fault will automatically clear 5 seconds after the car stops. The car is then allowed to run again.
2. Check for the proper positioning of the DETS switch in the hoistway.
6-63