MCi iControl User Manual page 364

For ac elevators
Table of Contents

Advertisement

Troubleshooting
Table 6.6 ICE-CTP Board Connections
Terminal
SHLD
Shield: Common
26V
26V output to load weigher
LW-
Input from Load Weigher (analog voltage)
LW+
Input from Load Weigher (analog voltage)
DP2-
Position input from iLand (balanced pair with DP2+)
DP2+
Position input from iLand (balanced pair with DP2-)
SHLD
Shield: Common
DP1-
Position input from iLand (balanced pair with DP1+)
DP1+
Position input from iLand (balanced pair with DP1-)
SHLD
Shield: Common
TX+
Transmit to iBox (connect to iBox terminal RX+)
TX-
Transmit to iBox (connect to iBox terminal RX-)
SHLD
Shield: Common
RX+
Receive from iBox (connect to iBox terminal TX+)
RX-
Receive from iBox (connect to iBox terminal TX-)
SHLD
Shield: Common
Table 6.7 ICE-CTP Board Testpoints
Testpoint
GND (x4)
Volt (x8)
LW
LW-
TP_LW
RSTOUT
CLKOUT
Figure 6.2 ICE-CTP Board Switches
• Computer Reset: Press to initialize the Cartop Processor board computer.
• Diagnostic Switches: Factory board test use only.
• Program Switch: Used at the factory during board programming.
• Learn Switch: Used at the factory during board programming.
• Test points: +5V, -15V, +15V, -26V, +26V, +3.3V, +E3.3V (emergency logic power pro-
vided by on board battery).
6-88 Manual # 42-02-2222
Ground testpoints
+2.5, +3.3, +5, -15V, +15V, -26V, +26V
Measured from LW to TP_LW, 0.3 — 1.0 VDC = Empty car.
Measured from LW- to TP_L@, -0.3 — -1.0 VDC = Empty car.
Measured from TP_LW to GND, 4 — 8 VDC = Full car.
0V= computer reset
33MHz microprocessor clock