Running On Machine Room Inspection - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Inspection Mode

Running on Machine Room Inspection

When you are ready to run the elevator on Inspection:
1. Verify the iBox Computer, Safety A, Safety B, and Cartop status LEDs are lighted solidly
green.
2. Move the Inspection switch to the INSP position.
3. Move the Controller Stop switch to the RUN position.
Within 5 seconds, the Safety OK and Doors Locked LEDs should be on and the Fault
LED should be off.
4. Verify that Car Door Bypass and Hall Door Bypass iBox switches are set to the OFF posi-
tion.
5. Verify that the car is in Machine Room Inspection on the iBox or in iView. If the car is in
another inspection mode (i.e., Cartop Inspection, In-car Inspection, or Hoistway
Access), turn them off. The INCT, INA, and INCP inputs on the left edge of the iBox
should be high (110VDC).
6. Press and hold the iBox Enable button, then press the Up or Down button to run the car
on inspection. Run the car away from the terminal landing.
7. On the iBox or on the iView Hoistway screen, verify car speed (Actual Speed). Use the
iBox or iView Actual Speed as the speed reference. Use TORQMAX drive parameter
LF22 to calibrate speed if required.
Control (TORQMAX)" on 2-55.
3-26 Manual # 42-02-2222
Please refer to "Verifying Car Direction and Motor

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents