Table 7.2 Mgmt Menu Parameters
Use to cancel write privilege which has been granted to an iView PC connected to the controller.
Use to change the write privilege timeout timer setting. The default value is 15 minutes.
This option is used for field replacement of an iBox. It allows the controller's parameter settings to
be saved to flash memory. That memory can then be transferred to the new iBox, thus eliminating
the need to manually enter and learn the parameter settings. Specific instructions for using this
feature are provided with the replacement iBox.

Setting iBox Ethernet Port Addresses

The table below lists the factory default addresses TCP/IP addresses. The iBox 3 = PC port (PC
direct) is set to 192.168.193.001 and should not be changed.
Table 7.3 System, LAN, & 3=PC TCP/IP Addresses
Hub
Group
System
all
LAN
A
LAN
B
LAN
C
LAN
D
LAN
E
Port #3 = PC (iBox ONLY), NO HUB
*192.168.191.101 is typically used for the iView PC.
The default Subnet Mask for all ports is 255.255.255.000.
The default Gateway for the #1 (LAN or Peripheral Port) is 192.168.191.254.
The default Gateway for the #2 and #3 ports is 000.000.000.000.
You should not need to change the factory-set IP information. If you are having problems con-
necting to an iBox Ethernet port, refer to the following topic to verify and, if necessary, set IP
addresses.
Note
The Group ID setting in iView determines the iCue System IP address at which iCue will accept
messages. NO NOT set the Group ID to a setting other than 1 unless instructed to do so
by MCE. Group IDs other than 1 are reserved for future use and will cause group-to-car commu-
nication to fail. If you need advanced System addressing information, please contact MCE.
Mgmt Menu Parameters
End Write Privilege
Write Privlge Timeout
Clone Controller Data
Group IP, Primary
Car ID
& Backup
192.168.192.201-202
1-20
192.168.191.201-202
1-20
192.168.191.203-204
1-20
192.168.191.205-206
1-20
192.168.191.207-208
1-20
192.168.191.209-210
1-20
Setting iBox Ethernet Port Addresses
System/Serial
Car IP
Hall Call Bus 1 - 4
192.168.192.001-020 192.168.192.211-214
192.168.191.001-020
192.168.191.021-040
192.168.191.041-060
192.168.191.061-080
192.168.191.081-100
192.168.193.001
iView PC
192.168.192.101-200*
7-9
7