Construction Mode
Figure 2.10 Simplex Controller Ethernet Example
SIMPLEX ETHERNET ADDRESS EXAMPLE
CAR
192.168.193.001
192.168.191.001
The table below lists the factory default addresses for elevator and group controllers. The #3
iBox port (PC=Direct) is set to 192.168.193.001 and should not be changed. Do not use leading
zeros when setting IP Addresses on a PC (i.e., .021 is entered as .21). (When entering IP
Addresses on the iBox keypad, you must use leading zeros.)
Table 2.3 System, LAN, & 3=PC TCP/IP Addresses
Hub
Group
System
all
LAN
1
LAN
2
LAN
3
LAN
4
LAN
5
Port #3 = PC (iBox ONLY), NO HUB
* 192.168.191.101 is typically used for the iView PC.
The default Subnet Mask for all ports is 255.255.255.000.
Please refer to "Setting iBox Ethernet Port Addresses" on page 7-9
IP settings on the iBox.
2-34 Manual # 42-02-2222
iView, Direct
PC used for Direct Connection
LAN HUB
Isolation
Board
Serial
Hall
Call
Driver
Group IP Primary
Car ID
& Backup
192.168.192.201-202
1-20
192.168.191.201-202
NA
192.168.191.203-204
NA
192.168.191.205-206
NA
192.168.191.207-208
NA
192.168.191.209-210
NA
192.168.193.2
255.255.255.0 Subnet Mask
0.0.0.0 ( . . . ) Gateway
BLUE CABLES
192.168.191.101
255.255.255.0
System/Serial
Car IP
Hall Call Bus 1 - 4
192.168.192.001-020 192.168.192.211-214
192.168.191.001-020
192.168.191.021-040
192.168.191.041-060
192.168.191.061-080
192.168.191.081-100
192.168.193.001
iView, LAN
PC used for LAN Connection
Subnet Mask
Free
192.168.192.101-120
192.168.191.101-200
192.168.191.101-200
192.168.191.101-200
192.168.191.101-200
192.168.191.101-200
for instructions on checking