MCi iControl User Manual page 667

For ac elevators
Table of Contents

Advertisement

• Hall call enable 1 (2) - Rear input: When active, a valid call for the rear opening on the
associated floor can be registered. Select floor number in Association column.
• Hall call enable 1 (2) - Main front input: When active, valid secured calls at the associ-
ated floor, main front riser, can be registered. Select floor number in Association col-
umn.
• Hall call enable 1 (2) - Main rear input: When active, a valid call at the associated
secured floor, main rear riser, can be registered. Select floor number in Association
column.
• Hall call enable 1 (2) - Aux front input: When active, a valid call at the associated
secured floor, auxiliary front riser, can be registered. Select floor number in Associa-
tion column.
• Hall call enable 1 (2) - Aux rear input: When active, a valid call at the associated
secured floor, auxiliary rear riser, can be registered. Select floor number in Association
column.
• Hall call enable 1 (2) - Down aux front input: When active, a valid call at the associated
secured floor, down auxiliary front riser, can be registered. Select floor number in
Association column.
• Hall call enable 1 (2) - Down aux rear input: When active, a valid call at the associated
secured floor, down auxiliary rear riser, can be registered. Select floor number in Asso-
ciation column.
• Hall call enable 1 (2) - Up aux front input: When active, a valid call at the associated
secured floor, up auxiliary front riser, can be registered. Select floor number in Associ-
ation column.
• Hall call enable 1 (2) - Up aux rear input: When active, a valid call at the associated
secured floor, up auxiliary front riser, can be registered. Select floor number in Associ-
ation column.
• Hall call enable 1 (2) - Down main front input: When active, a valid call at the associ-
ated secured floor, down main front riser, can be registered. Select floor number in
Association column.
• Hall call enable 1 (2) - Down main rear input: When active, a valid call at the associated
secured floor, down main rear riser, can be registered. Select floor number in Associa-
tion column.
• Hall call enable 1 (2) - Up main front input: When active, a valid call at the associated
secured floor, up main front riser, can be registered. Select floor number in Association
column.
• Hall call enable 1 (2) - Up main rear input: When active, a valid call at the associated
secured floor, up main rear riser, can be registered. Select floor number in Association
column.
NOTE: The inputs above are OR'ed together with the greater permission exerting control.
• CFSS call enable 1 (or 2) inputs
• CFSS call enable 1 (2) - CFSS mode 1 input: When active, a valid CFSS mode 1 call at
the associated secured floor, can be registered. Select the floor number in the Associa-
tion column. (CFSS mode 1 and 2 are user-assignable operating modes typically used
for medical emergency calls, attendant calls, etc.)
Configuration Tabs - System I/O
10
10-57

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents