Configuration - Floor Heights - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

iView - Controller View

Configuration - Floor Heights

The Configuration > Floor Heights > Configurations tab is used to view the learned values for
the floor heights.
• Level Up Top: The learned distance from the bottom floor to the top of the floor magnet as
determined by the Level Up sensor.
• Level Up Bottom: The learned distance from the bottom floor to the bottom of the floor
magnet as determined by the Level Up sensor.
• Level Down Top: The learned distance from the bottom floor to the top of the floor magnet
determined by the Level Down sensor.
• Level Down Bottom: The learned distance from the bottom floor to the bottom of the floor
magnet determined by the Level Down sensor.
Floor Offsets Tab
• Offsets: The variance from the floor magnet position to the
actual floor level position. The offset value is determined by
performing the floor offset calibration procedure (Setup >
Floor Heights > Floor Offsets).
the Floor Offsets" on page
9-94 Manual # 42-02-2222
Please refer to "Calibrating
4-23.