MCi iControl User Manual page 321

For ac elevators
Table of Contents

Advertisement

Table 6.3 iControl Messages
Inspection Operation, Inspection
Description: The car is operating in Inspection mode.
Car Reaction: One of the inspection modes (in-car, machine room, or cartop) is active. The car will operate
using the Inspection performance pattern.
Inspection Overspeed Fault
Description: While operating in Inspection mode, the car exceeded the Inspection Overspeed setting on the
iView Safety Configuration screen.
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
1. The fault will automatically clear 5 seconds after the car stops. The car is then allowed to run again.
2. If reported in error, check the Inspection Overspeed setting on the Safety Configuration screen.
3. Check the iView event log for any events immediately preceding the overspeed fault.
4. Determine and correct the cause of the overspeed.
Insufficient Brake Feedback Fault, INSFCNT BRK FDBK FLT
Description: Brake current feedback is abnormally low.
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
1. Check DB-25 connector from iField module to iBox is seated properly.
2. Check power supply on brake iField module.
3. Verify brake voltage parameters.
4. Verify iField Module setting for terminals FMCI and FMHC.
the ICE-FMP Board (Brake Module)" on page
5. Verify that the brake is properly calibrated.
Please refer to "Brake Parameter Adjustments" on page 4-20.
6. Check Brake voltage on the Operational Status tab. If the value goes below 0.00 volts, and/or the drive
offset (Input ADC) was recently calibrated or adjusted, verify / set the Input ADC = 0.0 on the Configu-
ration > Drive > Calibration tab.
Insufficient Motor Field Feedback Fault, INSFCNT MF FDBK FLT
Description: Indicates that Motor Current Feedback signal is less than 50% of the commanded field current.
Car Reaction: If detected four times over seven runs the car will shut down.
Troubleshooting:
1. Check motor field AC supply off isolation transformer.
2. Check connections from controller to motor.
3. Check connections to iField motor module.
4. Check for open fuses.
5. Recalibrate motor field.
Insufficient Motor Field Forcing Feedback Fault, INSFCNT MF FORCNG FLT
Description: Motor field voltage is inadequate. DC motors only.
Car Reaction:
Troubleshooting:
1. Verify motor field voltage parameters.
2. The motor field may be improperly calibrated. Check settings (iView Motor Configuration screen).
3. Recalibrate motor field if necessary.
Invalid Configuration BALRQ, INVALID CNFG BALRQ
Description: Bottom Access Landing Rear Qualifier. The safety system has detected the improper use of
BALRQ option on the iView safety configuration screen.
Car Reaction: Safety OK status remains off.
Troubleshooting:
1. Check that the Safety Configuration, Bottom Access Landing Rear option is properly set.
iControl Messages
Please refer to "IFIELD-MODULE Terminals on
6-95.
Please refer to "Drive Offsets Calibration" on page 2-48.
iControl Messages
6-45
6

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents