Table 11.3 iBox Field Connections
Source
Connection
UNTD
UNT5
UNT4
UNT3
UNT2
UETS
UNT1
DNT1
DETS
DNT2
DNT3
DNT4
DNT5
DNTD
Up Normal Limit Direction switch input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Up Slowdown Limit switch #5 input. 110 VDC = input on/switch closed.
0 VDC = input off/switch open.
Up Slowdown Limit switch #4 input. 110 VDC = input on/switch closed.
0 VDC = input off/switch open.
Up Slowdown Limit switch #3 input. 110 VDC = input on/switch closed.
0 VDC = input off/switch open.
Up Slowdown Limit switch #2 input. 110 VDC = input on/switch closed.
0 VDC = input off/switch open.
Up Emergency Terminal Limit switch input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Up Slowdown Limit switch #1 input. 110 VDC = input on/switch closed.
0 VDC = input off/switch open.
Down Slowdown Limit switch #1 input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Down Emergency Terminal Limit switch input. 110 VDC = input on/
switch closed. 0 VDC = input off/switch open.
Down Slowdown Limit switch #2 input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Down Slowdown Limit switch #3 input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Down Slowdown Limit switch #4 input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Down Slowdown Limit switch #5 input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
Down Normal Limit Direction switch input. 110 VDC = input on/switch
closed. 0 VDC = input off/switch open.
iBox Field Connections
Signal Description
11
11-9