Troubleshooting
Normal Operation
gives the normal operation display as follows:
Table 6.8 Diagnostic Indicators (Normal Operation - All DIP Switches OFF)
LED
1
Represents message input from iBox to iLink. With proper communication, toggles approx-
imately every 80mS. Goes OFF and stays OFF if input is lost.
2
Indicates that the cartop detected an unintended motion safety fault. With the car on Pas-
senger operation, after the car had reached a landing, the car moved at a speed greater
than 150 feet-per-minute.
3
Indicates that the cartop detected an unintended motion safety fault. With the car on
Inspection, after the car had reached a landing, the car moved with doors open.
4
Message output from iLink to iBox. With proper communication, toggles approximately
every 80mS. Goes OFF and stays OFF if output is lost.
5
This is the "alive" indicator. It toggles every 80mS during normal operation.
6
Lights when the car is on Inspection mode.
7
Unused.
8
Indicates that an interrupt is being serviced. If it goes off and stays off, the board is not
functioning normally and should be reset (press the RESET button).
When the iBox is not active, only LED 5 will toggle. When the iBox is active and normal opera-
tions are in progress, LEDs 1, 4 and 5 will toggle regularly.
Firmware Download
"Controller - Firmware Update" on page
the cartop. However, if a problem does develop, the following may be of use in recovering:
1. Set the S1 DIP switches 1, 6 and 8 = ON.
2. Press the manual Reset button on the ICE-CTP board. This tells the cartop firmware to
wait for a firmware download without attempting to run the normal cartop application
first.
3. Perform the firmware update using iView (File > Firmware Update).
Board Version
the DIP switches and LEDs 1 through 6 (ignore LEDs 7 and 8) The values are in hexadecimal,
with LED1 bring the 2
2 through 6 would be OFF (LEDs 7 and 8 are not part of the value and must be ignored).
• DIP switch 3 = ON, all others = OFF: Major version number displayed on LEDs.
• DIP switch 2 = ON, all others = OFF: Minor version number displayed on LEDs.
• DIP switch 1 = ON, all others = OFF: Revision number displayed on LEDs.
6-90 Manual # 42-02-2222
The normal operating condition is with all DIP switches OFF. This
Firmware updates can be downloaded via iView.
9-155. Normally, no manual intervention is needed at
The version and revision of the ICE-CTP board can be determined using
0