Construction Mode
Encoder Cables
tions are shown for illustration purposes only. Follow the job print instructions for your specific
encoder connections — they may be different than those shown here.
Induction Machine
Induction Machine
ENCODER
CABLE COLOR
CONFIGURATION
ENCODER
CONNECTOR
PIN LABEL
1
A (PIN3)
-A (PIN6)
B (PIN4)
-B (PIN7)
IEC
ENCODER
+V (PIN2)
0V (PIN1)
ENCODER
CABLE COLOR
ENCODER
CONFIGURATION
CONNECTOR
PIN LABEL
1
A (A)
-A (H)
B (B)
-B (J)
BEI
ENCODER
+V (D)
COM (F)
1
NO CONNECTION FOR SHIELD AT THIS END
ENCODER IS MOUNTED ON THE MOTOR SHAFT
2
ICE-SAF
ENCODER
TACH
2-26 Manual # 42-02-2222
The following illustration shows typical encoder wiring. These connec-
TORQMAX F5
SHIELD
X3A.1
+A
PURPLE
GRAY
X3A.2
-A
X3A.3
+B
GREEN
BLUE
X3A.4
-B
X3A.5
+N
X3A.6
-N
X3B.7
+5
WHITE
BLACK
X3B.8
COM
TORQMAX F5
SHIELD
X3A.1
+A
PURPLE
GRAY
X3A.2
-A
X3A.3
+B
GREEN
BLUE
X3A.4
-B
X3A.5
+N
X3A.6
-N
X3B.7
+5
WHITE
BLACK
X3B.8
COM
PM Machine
ENCODER
CABLE
COLOR
CONFIGURATION
ENCODER
CONNECTOR
1
LABEL
US
RED
GND
BLUE
REFSIN
BROWN
REFCOS
BLACK
HIPERFACE
ENCODER
DATA+
GREY
2
DATA-
GREEN
+SIN
WHITE
+COS
PINK
ENCODER
CABLE PIN
CONFIGURATION
ENCODER
CONNECTOR
1
LABEL
A(+)
1
A(-)
2
B(+)
11
B(-)
12
C(+)
5
C(-)
6
SIN/COS
ENCODER
D(+)
14
2
D(-)
4
R(+)
3
R(-)
13
+5V
10
COM
7
PM Machine
ENCODER
CABLE COLOR
CONFIGURATION
TORQMAX F5
HOUSING
X3A-10
WHITE
BLACK
X3A-13
X3A-4
PURPLE
GRAY
X3A-3
X3A-15
GREEN
BLUE
X3A-14
X3A-9
YELLOW
ORANGE
X3A-8
ENCODER
CABLE COLOR
CONFIGURATION
TORQMAX F5
HOUSING
X3A-8
GREEN
YELLOW
X3A-3
X3A-9
BLUE
RED
X3A-4
X3A-6
WHITE
BROWN
X3A-1
X3A-7
BLACK
PURPLE
X3A-2
X3A-15
GRAY
PINK
X3A-14
X3A-12
GRAY/PINK
WHITE/GREEN
X3A-13
+7V
COM
REF_SIN
REF_COS
+DATA
-DATA
SIN+
COS+
A(+)
A(-)
B(+)
B(-)
C(+)
C(-)
D(+)
D(-)
R(+)
R(-)
+5V
COM