iView - Controller View
• EP Car Selected to Run or Recall: This output is active when the car is selected to lower
or run on emergency power. Conditions that affect this operation are specified on the
Configuration > Car Operation > Emergency Power tab.
• Fan and Light Indicator: This output is normally off and will turn on when the car is at
rest long enough for the "Car fan and light timer" (Configuration > Car Operation >
Passenger tab) to time out.
• Fire I Light: This output is on when the car is in Fire phase I recall to the main or alter-
nate fire floor. It turns off when then-car firefighter's switch is activated.
• Fire II Light: Active when the in-car firefighters switch is active (fire phase II).
• Fire Recall: Active when the car is in Fire phase I recall to the main or alternate recall
floor.
• Fire Service Phase I Return Complete: This output is normally on and turns "off" to
indicate that the car has successfully completed the Fire service phase I recall function
(the car is positioned at the fire recall floor with its doors open). It turns back on when
phase 2 switch is turned on. It is most often used as a signal that it is O.K. to remove
power from the control equipment and start the machine room sprinklers.
• Fire Warning Buzzer: This output comes on when fire service phase I is initiated.
• Fire Warning Light: This output will be solid on during fire service phase I and II. The
output will flash only if the machine room or hoistway fire sensors have tripped.
• Firefighter's Panel Unlock: Activated when the car reaches the recall floor. Used to
unlock the fire panel.
• Flood Operation Buzzer: Active when the car is on Flood Operation (set parameters on
the Configuration > Car Operation > Flood Operation tab).
• Flood Operation Status: Active when the car is on Flood Operation (set parameters on
the Configuration > Car Operation > Flood Operation tab).
• Gate Release Solenoid: Typically used on horizontally sliding fully manual doors to
release the car gate and allow it to close. This output is ON when the hoistway doors
are closed and there is a demand to move the car. It is turned OFF when both car gates
are fully closed.
• Gong Enable Down Front: This output comes on whenever the car passes a floor with a
front opening in the DOWN direction and the passing floor going enable button has
been activated.
• Gong Enable Down Rear: This output comes on whenever the car passes a floor with a
rear opening in the DOWN direction and the passing floor going enable button has
been activated.
• Gong Enable Up Front: This output comes on whenever the car passes a floor with a
front opening in the UP direction and the passing floor going enable button has been
activated.
• Gong Enable Up Rear: This output comes on whenever the car passes a floor with a
rear opening in the UP direction and the passing floor going enable button has been
activated.
• Heavy Load: This output is activated when the load in the elevator exceeds the thresh-
old set for "hall call bypass" on the Configuration > Load Weigher tab. The "load sta-
tus" will only change once the car has stopped at a landing and has opened its doors.
• Hoistway Inspection: Active when the car is on Hoistway-Access Inspection operation.