Overview Of Typical Connection Locations - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Overview of Typical Connection Locations

The following diagram provides a general overview of component and connection locations
inside iControl. Because circuit boards in iControl are connected along a common bus, they may
be arranged differently or different boards may be used in different installations. Therefore,
specific connections might be in a location other than the one shown. This is only a general
overview. This is only a general overview. Use it in conjunction with the job prints when making
electrical connections.
inputs and outputs.
Field wiring for hoistway,
car, landing and load
weighing systems, and dis-
crete hall calls are all on
the left edge of the con-
troller.
High voltage connections
are primarily on the right
side of the cabinet under
the motor drive.
Outputs used to drive
customer peripherals.
Signal/Pin assignments
made in iView screens.
Customer peripheral
inputs (card read-
ers,etc.) Signal/Pin
assignments made in
iView screens.
CE serial fixture interface.
Floor indicators, etc.
Earthquake sensor I/O.
Tachometer, position
encoder, velocity
encoder, and serial link
from cartop processor.
Discrete car connections,
limit switches, hoistway,
and door system connec-
tions.
Safety I/O.
Spare I/O. Common,
120VAC, and 110VDC
buses.
Emergency Brake
connection
Rear door processing
Please refer to "iBox Field Connections" on page 11-7
Resistor Cabinet
ICE-MOR: Outputs
ICE-MIAC: Inputs
ICE-MIAC: Inputs
ICE-SF: Srl. Fixtures
ICE-EQ: Earthquake
iBox Panel
ICE-IMP: Main
Processor
ICE-IRB:
ICE-RG Rope Gripper
ICE-IRD Rear Door
Controller Cabinet Installation
for a list of specific
Motor Drive
Contactor
Motor contactor
AC connections.
wiring.
2
Line Filter
2-11

Advertisement

Table of Contents
loading

Related Products for MCi iControl

Table of Contents