iView - Controller View
• Rotodial Position Indicators II, Output 1—3: Outputs created for the "Rotodial" brand
position indicators. These three outputs change in a specified pattern to cause the
rotodial device to rotate in the appropriate direction. Outputs II will deactivate during
Fire Service.
• Hall lanterns - Front up
• Hall lantern - Front up, Floor 1—150: This output is generated to activate the front
door hall gong/lantern assembly. Options are set on the Configuration > Car Opera-
tion > Devices tab.
• Hall lanterns - Front down
• Hall lantern - Front down, Floor 1—150: This output is generated to activate the front
door hall gong/lantern assembly. Options are set on the Configuration > Car Opera-
tion > Devices tab.
• Hall lanterns - Rear up
• Hall lantern - Rear up, Floor 1—150: This output is generated to activate the rear door
hall gong/lantern assembly. Options are set on the Configuration > Car Operation >
Devices tab.
• Hall lanterns - Rear down
• Hall lantern - Rear down, Floor 1—150:This output is generated to activate the rear
door hall gong/lantern assembly. Options are set on the Configuration > Car Opera-
tion > Devices tab.
• Hall gongs - Front
• Hall gongs - Front, Floor 1—150: This output is generated to activate a separate front
door hall gong.
• Hall gongs - Rear
• Hall gongs - Rear, Floor 1—150: This output is generated to activate a separate rear
door hall gong.
• Motor and Drive
• Brake Holding Voltage: This output turns ON for hardware driven Brake picking to
Holding voltage. The Hold delay timer option is located on Configuration > Brake >
Timers tab.
• Motor Blower: This output for the Motor Blower is ON when car is in motion and for
the duration of the time setting of the Motor blower hold delay timer on the Configura-
tion > Drive > General tab.
• Sheave Brake Enable: Used to enable the emergency brake function. The Emergency
Brake - Sheave brake options must be selected on the Configuration > Safety tab.
• Melina PI display Outputs I (Left)
• Left Character 9—22: Outputs to the Melina position indicator for the left character.
Outputs I will stay active during Fire Service.
• Melina PI display Outputs I (Middle)
• Middle Character 9—22: Outputs to the Melina position indicator for the middle char-
acter. Outputs I will stay active during Fire Service.
• Melina PI display Outputs I (Right)
• Right Character 9—22: Outputs to the Melina position indicator for the right charac-
ter. Outputs I will stay active during Fire Service.