iView - Controller View
Drive - Safety Tab
Speed Reference
• Following error: Adjusts amount of error permitted between voltage from Tach/Encoder
and pattern voltage. When set to 75%, a 7.5VDC error is allowed between the Tach/
Encoder and pattern voltages (100% = 10VDC). If excessive error is detected, a Tach Error
Fault will be displayed.
9-90 Manual # 42-02-2222
Please refer to "Following Error Margin" on page