MCi iControl User Manual page 308

For ac elevators
Table of Contents

Advertisement

Troubleshooting
Table 6.3 iControl Messages
Emergency Medical Service Bypassed
Description: EMS is active but has been bypassed by another mode of operation.
Car Reaction: EMS service is bypassed and the car operates under the new mode of operation.
Troubleshooting:
1. Check the current mode of operation and the EMS user settings.
Emergency Medical Service Deactivated
Description: EMS has been deactivated.
Car Reaction: Car is returned to prevailing mode of operation.
Troubleshooting: NA
Emergency Medical Service In-Car Activated (Switch 'n'), EMS In-car (Switch 'n') (n = 1 or 2)
Description: EMS In-Car service is activated via the in-car EMS key-switch. This is also referred to as the
EMS Phase II operation.
Car Reaction: The car remains out of hall call service. Car calls are enabled again and the car can be dis-
patched from inside the car with car calls only. After answering a car call, doors will open automatically and
close with constant pressure on the Door Close Button only.
Troubleshooting:
1. The EMS In-Car can be terminated by taking the car to the EMS recall floor by registering a car call then
deactivating the in-car EMS switch.
2. The In-Car operation can also be terminated by simply removing the in-car EMS switch from the pre-pro-
grammed IO configuration.
3. Related inputs:
EMSCarSwitch0: Normally low
EMSCarSwitch1: Normally low
Emergency Medical Service Recall Activated (Switch 'n'), EMS Recall (Switch 'n') (n = 1 or 2)
Description: EMS recall is activated via one of the EMS recall key-switches located next to the designated
EMS elevator. This is also referred to as the EMS Phase I operation.
Car Reaction: Momentary activation of the EMS recall switch will initiate a recall to the user-defined EMS
Recall floor. The car removes itself from car and hall call service. Once at the EMS recall floor, the door oper-
ation is in accordance to the user-defined door operation under EMS recall operation. The car will remain on
EMS Phase I as long as the hall switch is activated. Once the hall switch is deactivated, the car will return to
normal operation upon expiration of a user-defined timer if the in-car switch is not activated within that time.
Troubleshooting:
1. Verify that none of the hall EMS recall switches is activated.
2. The EMS Recall operation can also be terminated by simply removing the in-car EMS switch from the pre-
programmed IO configuration.
3. Related inputs:
EMSHallSwitch0: Normally low
EMSHallSwitch1: Normally low
Emergency Power Activated
Description: Commercial power has been lost and power is now supplied by an emergency power generator.
Car Reaction: The car will make an emergency stop due to the momentary loss of power and will remain shut
down until commanded to either lower to a pre-determined floor or proceed to the next available floor. Once
all cars have reached a floor, one or more cars will be selected to run under the emergency power generator.
Troubleshooting:
1. Related inputs:
EPI: Active level field adjustable.
6-32 Manual # 42-02-2222