Car Calls - Mode Overrides - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Car Calls - Mode Overrides

On a per configuration, per authorizing signal basis, you can allow a car call security restriction
to be overridden when the car is operating in a selected mode or when the call is placed from a
selected source. To program the override:
1. Configuration: Select the configuration affected by these choices.
2. Signal: Select the signal which would have been required to enable the restricted car call
to be registered (Enable 1, Enable 2 or Passcode).
3. Selection: Select floors, and calls singly or in blocks as described previously
to "Car Calls - Configuration" on page
4. Choose the sources /operating mode(s) that will override (ignore) the car call security
restriction at the selected floor/riser.
• All: Car calls from all of the following sources and modes.
• OBD calls: Calls placed using the iBox On-board Display.
• Remote calls: Calls placed using iView or iMonitor.
• Automatic calls: Calls placed automatically by iControl, e.g.
• Automatic door open: Under certain conditions, including certain fault conditions
and emergency power transfer periods, the elevator doors may need to automati-
cally open or cycle open/closed at floors. Activating this override, allows the doors
to open or cycle even at a secured opening.
• Emergency dispatch: Calls generated as a result of emergency dispatching.
Configuration Tabs - Security
10-45).
(Please refer
10
10-47