Image Density Adjustment - Toshiba e-STUDIO520 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the codes to be adjusted (language and screen) and press the [START] button.
(3)
Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density (L) 1: Medium density (M) 2: High density (H)
(4)
Key in the adjustment value. (To correct the value once keyed in, press [CLEAR] button.)
(5)
Press the [ENTER] or [INTERRUPT] button to store the value in memory. ¨ The equipment goes
back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Let the equipment restart and perform printing job.
(8)
If the image density has not been attained, repeat step (1) to (7).
3.4.3

Image density adjustment

Adjust the image density level when normal printing (Toner save: Disable) and (Toner save: Enable).
Toner Saving
Normal
mode
PS/PCL
PS
PCL
663
664
665
<Procedure>
Procedure is same as that of
e-STUDIO520/523/600/603/720/723/850/853
ADJUSTMENT
< Adjustment Mode (05) >
Item to be adjusted
Image density adjustment
P.3-27 "3.4.1 Adjustment of smudged/faint text".
3 - 28
Remarks
The image density level in the Printer function can
be set.
The smaller the value is, the lighter the density of
image becomes.
Acceptable values: 0 to 255.