3.7.11

Reproduction ratio of primary scanning direction (black)

The reproduction ratio of primary scanning direction with the resolution other than 600 dpi is adjusted in
Scanning Function for black image.
Code
884
When the value increases, the image is zoomed in.
When the value decreases, the image is zoomed out.
Acceptable values: 0 to 255 (Default: 128)
* 0.1%/step
<Procedure>
Procedure is same as that of "3.7.2 Density adjustment".
3.7.12

Reproduction ratio of primary scanning direction (color)

The reproduction ratio of primary scanning direction with the resolution other than 600 dpi is adjusted in
Scanning Function for color image.
Code
1060
When the value increases, the image is zoomed in.
When the value decreases, the image is zoomed out.
Acceptable values: 0 to 255 (Default: 128)
* 0.1%/step
<Procedure>
Procedure is same as that of "3.7.2 Density adjustment".