10.7.8

Drum

(1)
Take off the main charger.
P.10-13 "10.7.4 Main charger"
(2)
Rotate the lever while pushing its latch and
pull it out.
(3)
Take off the drum.
Notes:
1. Be careful not to touch, spit or scratch the
drum surface.
2. Avoid direct light. Place the drum in a
dark place immediately after taking off.
3. Be careful not to touch or scratch the
edge of the cleaning blade.
10.7.9

Drum cleaning blade

(1)
Take off the drum.
P.10-15 "10.7.8 Drum"
(2)
Remove 2 screws and take off the drum
cleaning blade.
Note:
Be careful not to touch or scratch the edge of
the drum cleaning blade.

10.7.10 Drum separation finger

(1)
Take off the drum.
P.10-15 "10.7.8 Drum"
(2)
Take off 2 drum separation finger units by
removing 1 screw each.
Note:
When replacing the drum separation fingers,
make sure that the drum has been taken off
first since the fingers may scratch the drum
surface.