If3 Data A Register (Can If3Datb) [Offset = 0X154]; If3 Update Enable Register (Can If3Upd) [Offset = 0X160]; If3 Update Control Register Field Descriptions - Texas Instruments Concerto F28M36 Series Technical Reference Manual

Table of Contents

Advertisement

www.ti.com
31
15
LEGEND: R = Read; -n = value after reset
23.15.24 IF3 Update Enable Registers (CAN IF3UPD)
The automatic update functionality of the IF3 register set can be configured for each message object. A
message object is enabled for automatic IF3 update, if the dedicated IF3UpdE flag is set. This means that
an active NewDat flag of this message object (e.g due to reception of a CAN frame) will trigger an
automatic copy of the whole message object to IF3 register set.
NOTE: IF3 Update enable should not be set for transmit objects.
Figure 23-50. IF3 Update Enable Register (CAN IF3UPD) [offset = 0x160]
31
15
LEGEND: R/W = Read/Write; -n = value after reset
Bit
Field
31-0
IF3UpdEn[31:0]
SPRUHE8E – October 2012 – Revised November 2019
Submit Documentation Feedback
Figure 23-49. IF3 Data A Register (CAN IF3DATB) [offset = 0x154]
Data 7
R-0
Data 5
R-0
IF3UpdEn[32:17]
Table 23-26. IF3 Update Control Register Field Descriptions
Value
Description
IF3 Update Enabled (for all message objects)
0
Automatic IF3 update is disabled for this message object.
1
Automatic IF3 update is enabled for this message object. A message object is scheduled to be
copied to IF3 register set, if NewDat flag of the message object is active.
Copyright © 2012–2019, Texas Instruments Incorporated
24
23
8
7
R/W-0
IF3UpdEn[16:1]
R/W-0
CAN Control Registers
Data 6
R-0
Data 4
R-0
M3 Controller Area Network (CAN)
16
0
16
0
1603