T2: Pm Motor - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Note:
After Auto-Tuning is complete and you set the drive to Drive Mode, operate the motor in these conditions:
• Make sure that you connect all wiring between the drive and motor
• Make sure that a mechanical brake on the motor shaft is not locked
• Keep the motor-load ratio at 30%
• Hold constant speed for longer than 1 second at a minimum of 30% of the speed set in E1-06 [Base Frequency] (the default setting is
the same as the maximum frequency).
T1-13 No-load Voltage
No.
Name
(Hex.)
T1-13
No-load Voltage
(0BDC)

T2: PM MOTOR

T2 parameters set the Auto-Tuning input data for PM motor tuning.
Note:
The drive automatically sets these PM motor parameters:
• E1-xx [E1: V/F PARAMETER MOTOR 1]
• E5-xx [E5: PM MOTOR SETTINGS]
• F1-xx [F1: ENCODER] (CLV only)
T2-01 PM AutoTune Mode Select
No.
Name
(Hex.)
T2-01
PM AutoTune Mode Select
(0750)
Note:
For specialized motors, Rotational (Ld, Lq, R, back-EMF) tuning is recommended. Rotational Auto-Tuning rotates the motor to measure
the actual induction voltage constants for more accurate control than Stationary Auto-Tuning.
0 : PM Motor Parameter Settings
1 : PM Static Full AutoTune
2 : PM Static R Autotune
3 : Encoder Offset Autotune
4 : PM Rotary Autotune
T2-02 PMMot Code Selection
No.
Name
(Hex.)
T2-02
PMMot Code Selection
(0751)
Enter the motor code in T2-02 to automatically set parameters T2-03 to T2-14. When you are operating a
specialized motor or a non-Yaskawa motor designed, set T2-02 = FFFF and enter the data from the motor
nameplate or the motor test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor
codes.
T2-03 PMMot Motor Type
No.
Name
(Hex.)
T2-03
PMMot Motor Type
(0752)
0 : IPM Motor
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load voltage of the motor. If no-load voltage is necessary at rated speed for the motor
test report, set the voltage in this parameter. If the motor test report is not available, do not change
this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning for PM motors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor code for drives operating SMRA, SSR1, or SST4-series Yaskawa PM motors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of PM motor the drive will operate.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.11 T: AUTOTUNING
Default
(Range)
90% of T1-03
(400 V Class: 0.0 - 510.0
V)
Default
(Range)
0
(Determined by A1-02)
Default
(Range)
Determined by A1-02 and
o2-04
(0000 - FFFF)
Default
(Range)
1
(0, 1)
827
12