o2-07 Keypad Dir@Power-Up
No.
Name
(Hex.)
o2-07
Keypad Dir@Power-Up
(0527)
This parameter is enabled in these conditions:
• When b1-02 = 0 [Run Comm. Sel 1 = Keypad] or b1-16 = 0 [Run Comm. Sel 2 = Keypad]
• In LOCAL Mode
0 : Forward
1 : Reverse
o2-09 Region Code for Initialization
No.
Name
(Hex.)
o2-09
Region Code for
Initialization
(050D)
o2-23 Ext24V Off Warning Display
No.
Name
(Hex.)
o2-23
Ext24V Off Warning
Display
(11F8)
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : Disabled
The drive does not detect the loss of the 24-V external power supply.
1 : Enabled
The keypad shows the L24v [Ext. 24-V Power Supply Lost] indicator when the drive detects the loss of the 24-V
external power supply.
Note:
The minor fault signal is not output from H2-xx = 4 [Multi-Function Digital Out = Alarm].
o2-26 Ext24V Mode Warning Display
No.
Name
(Hex.)
o2-26
Ext24V Mode Warning
Display
(1563)
0 : Disabled
The drive will not detect EP24v [External Power 24V Supply] if the main circuit power supply voltage decreases.
The [Ready] light on the LED Status Ring flashes quickly to identify that drive operation is not possible.
1 : Enabled
The drive detects EP24v when the main circuit power supply voltage decreases.
Note:
The minor fault signal is not output from H2-xx = 4 [Multi-function Digital Out = Alarm].
o2-27 BLE Disconn.Selection@BLE Ctrl
No.
Name
(Hex.)
o2-27
BLE Disconn.
Selection@BLE Ctrl
(1565)
0 : Ramp->Stop
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and the keypad is the Run
command source.
-
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to give a warning when the backup external 24 V power supply turns off when
the main circuit power supply is in operation.
V/f
CL-V/f
OLV
CLV
AOLV
When you connect a backup external 24 V power supply, this parameter sets the function to
trigger an alarm when the main circuit power supply voltage decreases.
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in
Bluetooth Mode.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.10 o: KEYPAD
Default
(Range)
0
(0, 1)
Default
(Range)
-
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
3
12
(0 - 4)