C5-28 M2 ASR Intgl Limit
No.
Name
(Hex.)
C5-28
M2 ASR Intgl Limit
(035D)
C5-29 Speed Ctrl Response Mode
No.
Name
(Hex.)
C5-29
Speed Ctrl Response Mode
(0B18)
Expert
If a high level of speed control responsiveness is necessary, set C5-29 = 1,then adjust the speed control (ASR)
parameter.
0 : Standard
1 : High Perf 1
C5-32 M2 I Oper@Ac/Dec
No.
Name
(Hex.)
C5-32
M2 I Oper@Ac/Dec
(0361)
If you enable integral operation when you are driving a heavy load or a high inertia load, it could cause problems
with overshoot or undershoot at the end of acceleration and deceleration. If there are problems with overshooting
and undershooting, set this parameter to 0.
0 : Disabled
Integral operation is not enabled during acceleration or deceleration. Integral operation is always enabled during
constant speed.
1 : Enabled
Integral operation is always enabled.
C5-37 M2 Inertia
No.
Name
(Hex.)
C5-37
M2 Inertia
(0278)
Expert
The drive automatically sets C5-37 to the value of [Motor Inertia] when you do Inertia Tuning or ASR Tuning.
C5-38 M2 Inertia Ratio of load
No.
Name
(Hex.)
C5-38
M2 Inertia Ratio of load
(0279)
Expert
The drive automatically sets C5-38 to the value of [Load Inertia Ratio] when you do Inertia Tuning or ASR
Tuning.
C5-39 ASR Delay Time 2
No.
Name
(Hex.)
C5-39
ASR Delay Time 2
(030D)
If you have a load with low rigidity or if oscillation is a problem, increase this setting in 0.01 unit increments.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for ASR for motor 2 as a percentage of the rated load.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level of speed control responsiveness. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets integral operation during acceleration and deceleration for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor inertia for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the load inertia ratio for the motor 2 inertia.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant for the time from the speed loop to the torque command output for
motor 2. Usually it is not necessary to change this setting.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.3 C: TUNING
Default
(Range)
400%
(0 - 400%)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
Determined by o2-04 and
C6-01
2
(0.0001 - 6.0000 kgm
)
Default
(Range)
1.0
(0.0 - 6000.0)
Default
(Range)
0 ms
(0 - 500 ms)
12
583