6A: DataLog Error
Setting
Function
6A
DataLog Error
90 to 93: Q2pack DO1 to 4
Setting
Function
90 to 93
Q2pack DO1 to 4
A0 to A7: Q2pack ExDO1 to 8
Setting Value
Function
A0 to A7
Q2pack ExDO1 to 8
100 to 1A7: Inverse Output of 0 to A7
Setting
Function
100 to 1A7
Inverse Output of 0 to A7
For example, set H2-xx = 103 for the inverse output of 3 [Fault].

H3: ANALOG INPUTS

Multi-Function Analog Inputs
WARNING! Sudden Movement Hazard. Do test runs and examine the drive to make sure that command references are
configured correctly. If you set the command reference incorrectly, it can cause death, serious injury, or equipment damage from
unwanted motor rotation.
Drives have three analog input terminals, terminals AI1, AI2, and AI3. H3 parameters select the functions set to
these analog input terminals and adjust signal levels.
Table 12.49
shows the functions that you can set to analog input terminals. Use H3-02 [AI1 Function Selection],
H3-06 [AI3 Function Selection], and H3-10 [AI2 Function Selection] to set functions.
Setting
0
Through Mode
1
AuxFreqRef1
2
AuxFreqRef2
3
Freq Ref/BIAS
4
FrqBIAS Frq
5
Freq Gain
6
OutVolt Bias
7
TorqCompensation
8
TorqRef/Lim
9
FW Trq Lim
B
Rev Trq Lim
C
RegenTrqLim
D
GenerTrqLim
Note:
All analog input scaling uses gain and bias for adjustment. Set the gain and bias values correctly.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Q2pack digital output. Refer to the Q2pack online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the digital output for the Q2pack DO-A3 option card. Refer to the Q2pack online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which function to
inversely output.
Table 12.49 AI Setting Values
Function
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Setting
E
OvUntrq Level
F
PID Fbk
10
PID SetPoint
11
Diff PIDFbk
12
AcDcTimeGain
13
DCInjBrakCurr
14
StallPLev@Rn
15
OutFLowLimSel
16
Mot PTC Input
30
Q2pack AI1
31
Q2pack AI2
32
Q2pack AI3
12.7 H: TERMINALS