12.11 T: Autotuning; T0: Tune Mode; T1: Induction Motor - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

12.11 T: AUTOTUNING

12.11 T: AUTOTUNING

Numbers identifying the T parameters are displayed when an LED keypad is used. The names of the parameters
are displayed on the LCD screen of the LCD keypad. Set the following.
• Induction Motor Auto-Tuning
• PM Motor Auto-Tuning
• ASR and Inertia Tuning

T0: TUNE MODE

T0-00 Tune Mode Selection
When your control method supports Control Tuning, set T0-00 first. Then, set T1-00 [Mot1/Mot2 Selection] to
select the motor you will tune. Then, set the tuning mode in T2-01 [PM AutoTune Mode Select] or T3-00 [Control
Loop Tune Selection].
No.
Name
(Hex.)
T0-00
Tune Mode Selection
(1197)
0 : Motor Parameter Tuning
1 : Control Tuning
Note:
The available tuning modes are different for different control methods.

T1: INDUCTION MOTOR

T1 parameters set the Auto-Tuning input data for induction motor tuning.
Note:
• The base frequency of drive dedicated motors and special motors for use with vector control may be lower than the base frequency of
general-purpose motors, which is 50 Hz or 60 Hz. In such cases, this lower frequency is used as the value for E1-06 [Base Frequency]
and E1-04 [Max Output Frequency] after Auto-Tuning completes. If the maximum output frequency is too low and causes problems,
change the setting of E1-04 after Auto-Tuning completes.
• The following induction motor parameters are set automatically.
–E1: V/F PARAMETER MOTOR 1
–E2: MOTOR 1 PARAMETERS
–E3: V/F PARAMETER MOTOR 2
–E4: MOTOR 2 PARAMETERS
–F1: ENCODER (only with Closed Loop Vector Control)
T1-00 Mot1/Mot2 Selection
No.
Name
(Hex.)
T1-00
Mot1/Mot2 Selection
(0700)
Note:
Set H1-xx = 16 [Motor 2 Selection] ON to set this parameter. The keypad will not show this parameter when H1-xx = 16 is OFF.
1 : Motor 1 (sets E1-xx, E2-xx)
Auto-Tuning automatically sets parameters E1-xx and E2-xx for motor 1.
2 : Motor 2 (sets E3-xx, E4-xx)
Auto-Tuning automatically sets parameters E3-xx and E4-xx for motor 2. Make sure that you connect motor 2 to
the drive for Auto-Tuning.
824
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning.
V/f
CL-V/f
OLV
CLV
AOLV
Sets which motor to tune when motor 1/2 switching is enabled. You can only use the keypad to set
this parameter. You cannot use external input terminals to set it.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
0
(0, 1)
Default
(Range)
1
(1, 2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents