11.6 E: MOTOR
No.
Name
(Hex.)
E5-04
PM Mot Pole Count
(032C)
E5-05
PM Mot Resistance
(Ohms/Phase)
(032D)
E5-06
PM d-Axis Inductance
(mH/Phase)
(032E)
E5-07
PM q-Axis Inductance
(mH/Phase)
(032F)
E5-09
PM BackEMF Vpeak
(mV/(rad/ s))
(0331)
E5-11
Enc ZPulse Offset
(0333)
E5-24
PM BackEMF L-L Vrms
(mV/rpm)
(0353)
E5-25
Polar Est Timeout
(035E)
Expert

E9: SIMPLE VECTOR SETTINGS

No.
Name
(Hex.)
E9-01
Motor Type Selection
(11E4)
E9-02
Maximum Speed
(11E5)
E9-03
Rated Speed
(11E6)
E9-04
Base Frequency
(11E7)
E9-05
Base Voltage
(11E8)
E9-06
Motor Rated Current
(11E9)
E9-07
Motor Rated Power
(kW)
(11EA)
E9-08
Motor Pole Count
(11EB)
E9-09
Motor Rated Slip
(11EC)
E9-10
Motor L-L Resistance
(11ED)
418
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PM motor poles.
Note:
• When A1-02 = 7 [Control Method = PM CLVector], the maximum value is 120.
• When A1-02 = 5, 6 or 8 [PM OLVector, PM AOLVector or EZ Vector], the
maximum value is 48.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the resistance per phase of the PM motors. Set 50% of the line-to-line resistance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor d-axis inductance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor q-axis inductance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the peak value of PM motor induced voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the encoder Z-pulse offset.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the RMS value for PM motor line voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that switches polarity for initial polarity estimation. Usually it is not
necessary to change this setting.
0 : Disabled
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of motor.
0 : IM (Induction)
1 : PM (Permanent Magnet)
2 : SynRM (Synchronous Reluctance)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum speed of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated rotation speed of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated frequency of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated power in 0.01 kW increments (1 HP = 0.746 kW).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor stator windings.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
Determined by E5-01
624
(2 - 120)
Determined by E5-01
625
(0.000 - 65.000 Ω)
Determined by E5-01
625
(0.00 - 300.00 mH)
Determined by E5-01
625
(0.00 - 600.00 mH)
Determined by E5-01
625
(0.0 - 2000.0 mV/(rad/s))
0.0 degrees
625
(-180.0 - +180.0
degrees)
Determined by E5-01
626
(0.0 - 6500.0 mV/min
-1
)
0
626
(0, 1)
Default
Ref.
(Range)
0
626
(0 - 2)
Determined by E9-01
626
(40.0 - 120.0 Hz)
Determined by E9-01
627
(100 - 7200 min
-1
)
Determined by E9-01
627
(40.0 - 120.0 Hz)
Determined by E9-01
627
(400 V Class: 0.0 to
510.0 V)
Determined by E9-01
202
and o2-04
(10% to 200% of the
drive rated current)
Determined by E9-02
627
and o2-04
(0.00 - 650.00 kW)
4
627
(2 - 120)
0.0 Hz
628
(0.0 - 20.0 Hz)
Determined by o2-04
628
(0.000 - 65.000 Ω)

Hide quick links: